100BA is a high speed (fast recovery) dual diode module designed for high
power switching application. FRD
FDS100BA is suitable for high frequency
application requiring low loss and high speed control.
High Speed t
rr
100ns
I
F
AV
100A
each device
Isolated mounting construction.
High Surge Capability
Applications
Switching Power Supply, Inverter Welding Power
Supply
Power Supply for Telecommunication
Maximum Ratings
Tj25 unless otherwise specified
Symbol
Item
Ratings
600
480
Unit
V
RRM
V
R
DC
Repetitive Peak Reverse Voltage
D.C. Reverse Voltage
V
V
Symbol
Item
Forward Current
Conditions
Ratings
Unit
A
I
F
D.C. Tc
94
100
I
FSM
Surge Forward Current
1
2
cycle, 60H
Z
, peak value, non-repetitive
2000
A
I
2
t
I
2
t
Value for One cycle of surge curent
16700
A
2
S
Tj
Operating Junction Temperature
-40 to 150
Tstg
Storage Temperature
-40 to 125
V
ISO
Isolation Breakdown Voltage
R.M.S.
Mounting
Torque
A.C. 1 minute
2500
V
Mounting
M6
Terminal
M5
Mass
Recommended Value 2.5-3.9
25-40
Recommended Value 1.5-2.5
15-25
4.7
48
2.7
28
Nm
fB
g
170
93.5MAX
26MAX
30MAX
13
21
80
16.5
23
3
~
+
2
1
23
3M5
2-
6.5
Unit
Electrical Characteristics
Symbol
I
RRM
Item
Repetitive Peak Reverse Current, max.
Conditions
V
R
V
RRM
, T
j
125
Ratings
Typ.
Max.
1.15
85
100
1.3
0.4
100
Unit
mA
V
FM
Forward Voltage Drop, max.
Forward current 100A, Inst. measurement
V
Rth
j-c Thermal Impedance, max.
Junction to case
/W
trr
Reverse Recovery Time, max.
I
F
100Adi/dt-100A/s
ns
FDS
FRD
SanRex
50 Seaview Blvd. Port Washington, NY 11050-4618 PH.(516)625-1313 FAX(516)625-8845 E-mail: semi@sanrex.com
FRD/FDS100BA60
Forward Characteristics
Forward Voltage Drop V
F
V
Forward Current I
F
A
Typical
Tj25
Max.
TimeCycles
Cycle Surge Forward Current Rating
Non-Repetitive
0
1
2
Surge Forward Current
A
Tj25 Start
60Hz
Time
t
sec
Transient Thermal Impedance
-3
-2
-1
-0
Transient Thermal Impedance
j-c
/
W
Junction to Case
Per one element
Reverse Recovery Characteristics
Forward Current I
F
A
Reverse Recovery Time trr
s
Reverse Recovery Charge


Reverse Recovery Current



0
2
2
0
2
-1
1
2
2
-1
2
-
0
Qrr
Qrr
lrr
lrr
trr
trr
25
125
-di/dt100As
Typical
Reverse Recovery Characteristics
-di/dtA/s
Reverse Recovery Current



Reverse Recovery Charge


Reverse Recovery Time t


s
0
-1
1
2
1
3
I
F
100A
Typical
Qrr
Qrr
lrr
lrr
trr
trr
25
125
SanRex